Inspiration 潛水者的靈魂
1997年起,自全密閉循環水肺開發以來,已獲得無數獎項,市場銷售量也居冠。
3公升氣瓶,易於準備和保養,Inspiration為潛水者調節適當的氣體消耗量、氣體混合比,使潛水者能夠勇往直前!目前是休閒潛水員、製片商、專業潛水人員的優選,可潛至100m深水。

Inspiration with Vision Electronics
     
Dimensions (h x w x d): 65cm x 45cm x 35cm
Boxed Dimensions (l x w x d): 72cm x 53cm x 39cm
Weight: 29kg
Colour Options: Grey/Black
Yellow/Black
Integrated Weight Harness Sizes: S M L XL XXL
Counterlung Sizes: M L XL
Weight of Sofnolime (nominal): 2.5kg
Absorbent duration (797) (4°C, 40RMV, 1.g lpm CO2): 3 hours
O2 Cylinder: 1 x 3 litres
Diluent Cylinder: 1 x 3 litres
Wing Sizes: 16kg or 22.5kg
Standard Features: Trim Weight Pockets; Auto Air for OC Bailout; Dive Timer; APD Communicator Software and PC Interface; Logviewer Software; Software Upgradable; Head Up Displays; Dual Power Supplies; Audible Warnings; Battery Status Indicator; Sealed Battery Box; Automatic Setpoint Switch
Optinal Features: Automatic Diluent Valve (ADV); Nitrox Deco Software; Trimix Deco Software; CO2 Scrubber Monitor; APD Divestore USB Memory
Atmospheric Range: 650 - 1080 mbar
Battery (6v Lithium): The preferred brand is Fujitsu Lithium 6 volt, type CRP2. In use this battery has proven to have a greater capacity than other brands, giving proper solenoid operation within the voltage warnings provided by the electronics and for longer life.
Buoyancy Compensator: Wing style - 16kg and 22.5kg
Counterlung Volume: Medium - 11.4kg (5.7 litres per counterlung)

Large & XL - 14 litres (7 litres per counterlung)

Cylinders: Two 3-litre steel cylinders, one oxygen, one diluent (M25 x 2 cylinder thread, 3/4" NPSM - USA)
Depth Limits: 40m - max. Depth with air diluent.
100m - max. Depth at which all rebreather parameters are proven: CO2 endurance, O2 control and work of breathing.
100m - the limit of the CE approval.
110m - max. Depth at which the work of breathing has been tested using Trimix diluent.
150m - max. Depth at which the work of breathing has been tested with an Heliox diluent.
160m - Depth at which all components are pressure tested during type approval (not during production).

WARNING! Diving deeper than 100m carries the following additional risks.

Deeper than 100m: CO2 endurance unknown.
Deeper than 100m: Onboard decompression invalid.
Deeper than 110m: Work of breathing with a Trimix diluent unknown.
Deeper than 130m: Depth gauge inaccurate.
Deeper than 150m: Work of breathing with an Heliox diluent unknown.
Deeper than 160m: Structural integrity of components unknown - the air cavity within the buzzer will implode eventually, and other components may fail.

Display accuracy: ± 0.05 bar
Display Resolution: 0.01 bar
First stage (Oxygen): Intermediate Pressure - 7.5 to 8.0 bar
First stage (Diluent): Intermediate Pressure - 9.0 to 9.5 bar
Hydrostatic Imbalance: <1.0 kPa (10mbar) in all rotations
Oxygen Control: Two oxygen pressure setpoints, switchable from low to high and high to low as often as required, both underwater and on the surface.
Oxygen Sensors: 3 Galvanic cells, APD10
Oxygen setpoint range (Low): 0.5 to 0.9 bar
Oxygen setpoint range (High): 0.9 to 1.5 bar
Oxygen warning level (Low): 0.4 bar
Oxygen warning level (High): 1.6 bar
Languages: English; Dutch; French; German; Italian; Portuguese; Spanish.
Rebreather Operating Temperature Range:


 

+4°C to +32°C
Short term air storage (hours): -10°C to +50°C
Long term storage: +5°C to +20°C

The rebreather operating temperature range is determined at the cold end by the CO2 duration trials, which are done at 4°C(±1). Below this temperature the duration of the CO2 absorbent has not been empirically determined. If stored below 0°C the CO2 absorbent and electronics will need gentle pre-heating prior to use by placing in a warmer room or by submersing the assembled rebreather with mouthpiece closed (loop sealed) until the temperature of the equipment matches the ambient temperature. Below 0°C the liquid crystal display in the handset freezes to a solid black and is unusable. Water is an essential part of the CO2 absorption reactions (approx. 17% of Sofnolime is water), below freezing point the first reaction where CO2 and water react to form Carbonic acid cannot take place. If a pre-breathing method of warming the Sofnolime is used, this must be done on land under supervision.

Shelf life of oxygen cells: 18 months
Shelf life of unused rebreather: When stored in accordance with BS3574 the shelf life is 7 years. (derived from the hoses and seals)
Ambient Pressure Diving Ltd. - Copyright 2007